Solar charging issues are often buried in portal data — CT clamp readings, generation curves, and export logs tell the real story. We review your monitoring data remotely and identify the exact cause.
Book your free remote diagnosticGivEnergy hubNot affiliated with GivEnergy Ltd. Independent diagnosis and repair.
I have a GivEnergy system consisting of two batteries, two inverters and a controlling EMS (Energy Management System) which has not worked since Nov 2025. After six months I discovered Solar Tech Support, reached out to them and Ron phoned me back – how often do you get that service? Could not be more helpful – worked directly with me over the phone, outside what I would call normal working hours. Lucid explanations and we were able to discuss the issues and history using camera and email history. As this was a very rare setup, Ron was able to access an EMS expert in the field to confirm the solution. One sunny day in, I am now only paying for standing charge and a few pence for spikes in grid consumption while battery catches up with house demand.
When my GivEnergy system had an issue, I was completely left without support and had honestly lost all hope. Thankfully, I searched online and found Ron, which completely turned things around. After sending him a message, he responded incredibly fast and called me to assure me that he would get the problem fixed. I really admire his dedicated, supportive nature and his determination to find a solution. With this kind of outstanding attitude and customer service, he has absolutely secured a future customer in me.
Ron want out of is way to help, nothing was to much. He was very thorough in what he did Very knowledgeable I would highly recommend Ron and his company He did a fantastic job for me. if you have any problems, he'll do his best to help you out and resolve your problem. I wouldn't hesitate to recommend them
Ron took me through a diagnostic to confirm my GivEnergy Inverter had a fault. A common one as it turns out with the AC Inverter. As GivEnergy is defunct there is no immediate fix, aside from sourcing 2nd hand replacement. It may be that a fix becomes available over the summer which would make a lot of GivEnergy customers happy (Again)
Contacted Ron with a problem and he sorted it out quickly with no problems at all. Very knowledgeable on anything solar/ batteries. I would recommend him to anyone
I've spoken to Ron a couple of times with issues with my Givenergy installation. Such a friendly knowledge guy very highly recommended. Thank you very much for resolving my issues
Contacted Solar Tech Support in desperation. After explaining the issues I had with my system a diagnosis was made and a solution proposed. Fantastic service, even contacted a manufacturer to arrange replacement parts for me. Great communications, explained all they were doing and what I had to do, clearly and precisly. Followed up to confirm all was ok. Excellent service.
After GivEnergy went into liquidation, just my luck, my battery started playing up (internal board crashed). Contacted my installer - not interested! Found Solar tech support on a Google search. Sooo glad I found this company! Ron is extremely helpful and has plenty of experience. He soon confirmed what the fault was, and helped me to get my system up and running again. Now moved my GivEnergy account to Solar tech support, and will definitely use again if I have more issues. Unusual to find such a helpful company in these times, no morons reading scripts, just direct contact with the engineer.
Contacted Solar Tech Support when trying to understand what my Givenergy inverter problem might be and what might be my options. Received good/honest advise which backed up my thoughts.
Ron is a super star. Two months ago my GivEnergy battery failed a firmware upgrade leaving it a brick. My installer couldn't/wouldn't fix it. GivEnergy couldn't/wouldn't fix it. Then they went into administration and all hope was lost. A flurry of emails later and Ron had diagnosed the fault (failed USB flash drive, something I'd suspected) and talked me through resolving it. Two months of nothing resolved in about 3 hours. It's great to work with someone who pays attention to the details, knows that they're doing (not just following a script) and gets stuff sorted without a fuss or up-charging.
I can add to the list of customers who had already 'given up' on GivEnergy due to their appalling customer service, and that was before they went into administration (their Trustpilot reviews don't lie!). So you can imagine my desperation when, having changed my ISP and my Inverter, predictably, proving to be the only device that didn't connect automatically to my new network, I found zero prospect of any customer support with GivEnergy having called in the administrators just five days earlier! The salvation came from Solar Tech Support. My IT advisor stumbled across their web site and some very helpful tips for beleaguered GivEnergy customers, as well as an offer to provide direct assistance. Nothing ventured, I decided to drop them an E-Mail, with very low expectations based on my experience of GivEnergy customer support. Within an hour Ron had responded with some pin point advice, and after a few exchanges of E-Mails he had nailed the problem, enabling the combined efforts of my IT advisor and solar installer to resolve it and reconnect my Inverter. Thank you Solar Tech Support, and Ron in particular, for coming to the aid of a deserted and despondent GivEnergy customer. Expert, razor sharp advice and first class customer service, even though I wasn't officially a customer.
This company are a rare gem, I had a very unusual problem following a failed firmware upgrade on my GivEnergy kit. I then found out GivEnergy were in administration and had dismissed all their support staff! None of the usual fixes to try and restore my inverter comms would work, and I looked everywhere, forums, GivEnergy youtube support videos - even AI couldn't figure it out. My installer was talking about huge sums for system replacements, and being vague / evasive about if they'd even install replacement GivEnergy inverter. Enter Solar Tech Support, reassuring and knowledgeable from the very start, I've learnt loads about my solar system though the friendly chat while my engineer worked as he diagnosed the problem and figured out a fix procedure that I've not found anywhere else - amazing . If you need solar system repairs - especially if you like me have been left high and dry by GivEnergy, I cannot recommend this company enough. Give them a call.
I sent a message on their website regarding a problem I have on my Givenergy system. Although not supplied by Ronald, I thought it was worth an email. Within the hour on a Saturday, he phoned and we discussed the problem. He logged in remotely and gave excellent advice. I'm too far away for his on-site help but he did diagnose the problem and was happy also to chat through my thoughts about an upcoming solar/battery install I'm planning. Great bloke.... if only he was nearer!
I have a GivEnergy system consisting of two batteries, two inverters and a controlling EMS (Energy Management System) which has not worked since Nov 2025. After six months I discovered Solar Tech Support, reached out to them and Ron phoned me back – how often do you get that service? Could not be more helpful – worked directly with me over the phone, outside what I would call normal working hours. Lucid explanations and we were able to discuss the issues and history using camera and email history. As this was a very rare setup, Ron was able to access an EMS expert in the field to confirm the solution. One sunny day in, I am now only paying for standing charge and a few pence for spikes in grid consumption while battery catches up with house demand.
When my GivEnergy system had an issue, I was completely left without support and had honestly lost all hope. Thankfully, I searched online and found Ron, which completely turned things around. After sending him a message, he responded incredibly fast and called me to assure me that he would get the problem fixed. I really admire his dedicated, supportive nature and his determination to find a solution. With this kind of outstanding attitude and customer service, he has absolutely secured a future customer in me.
Ron want out of is way to help, nothing was to much. He was very thorough in what he did Very knowledgeable I would highly recommend Ron and his company He did a fantastic job for me. if you have any problems, he'll do his best to help you out and resolve your problem. I wouldn't hesitate to recommend them
Ron took me through a diagnostic to confirm my GivEnergy Inverter had a fault. A common one as it turns out with the AC Inverter. As GivEnergy is defunct there is no immediate fix, aside from sourcing 2nd hand replacement. It may be that a fix becomes available over the summer which would make a lot of GivEnergy customers happy (Again)
Contacted Ron with a problem and he sorted it out quickly with no problems at all. Very knowledgeable on anything solar/ batteries. I would recommend him to anyone
I've spoken to Ron a couple of times with issues with my Givenergy installation. Such a friendly knowledge guy very highly recommended. Thank you very much for resolving my issues
Contacted Solar Tech Support in desperation. After explaining the issues I had with my system a diagnosis was made and a solution proposed. Fantastic service, even contacted a manufacturer to arrange replacement parts for me. Great communications, explained all they were doing and what I had to do, clearly and precisly. Followed up to confirm all was ok. Excellent service.
After GivEnergy went into liquidation, just my luck, my battery started playing up (internal board crashed). Contacted my installer - not interested! Found Solar tech support on a Google search. Sooo glad I found this company! Ron is extremely helpful and has plenty of experience. He soon confirmed what the fault was, and helped me to get my system up and running again. Now moved my GivEnergy account to Solar tech support, and will definitely use again if I have more issues. Unusual to find such a helpful company in these times, no morons reading scripts, just direct contact with the engineer.
Contacted Solar Tech Support when trying to understand what my Givenergy inverter problem might be and what might be my options. Received good/honest advise which backed up my thoughts.
Ron is a super star. Two months ago my GivEnergy battery failed a firmware upgrade leaving it a brick. My installer couldn't/wouldn't fix it. GivEnergy couldn't/wouldn't fix it. Then they went into administration and all hope was lost. A flurry of emails later and Ron had diagnosed the fault (failed USB flash drive, something I'd suspected) and talked me through resolving it. Two months of nothing resolved in about 3 hours. It's great to work with someone who pays attention to the details, knows that they're doing (not just following a script) and gets stuff sorted without a fuss or up-charging.
I can add to the list of customers who had already 'given up' on GivEnergy due to their appalling customer service, and that was before they went into administration (their Trustpilot reviews don't lie!). So you can imagine my desperation when, having changed my ISP and my Inverter, predictably, proving to be the only device that didn't connect automatically to my new network, I found zero prospect of any customer support with GivEnergy having called in the administrators just five days earlier! The salvation came from Solar Tech Support. My IT advisor stumbled across their web site and some very helpful tips for beleaguered GivEnergy customers, as well as an offer to provide direct assistance. Nothing ventured, I decided to drop them an E-Mail, with very low expectations based on my experience of GivEnergy customer support. Within an hour Ron had responded with some pin point advice, and after a few exchanges of E-Mails he had nailed the problem, enabling the combined efforts of my IT advisor and solar installer to resolve it and reconnect my Inverter. Thank you Solar Tech Support, and Ron in particular, for coming to the aid of a deserted and despondent GivEnergy customer. Expert, razor sharp advice and first class customer service, even though I wasn't officially a customer.
This company are a rare gem, I had a very unusual problem following a failed firmware upgrade on my GivEnergy kit. I then found out GivEnergy were in administration and had dismissed all their support staff! None of the usual fixes to try and restore my inverter comms would work, and I looked everywhere, forums, GivEnergy youtube support videos - even AI couldn't figure it out. My installer was talking about huge sums for system replacements, and being vague / evasive about if they'd even install replacement GivEnergy inverter. Enter Solar Tech Support, reassuring and knowledgeable from the very start, I've learnt loads about my solar system though the friendly chat while my engineer worked as he diagnosed the problem and figured out a fix procedure that I've not found anywhere else - amazing . If you need solar system repairs - especially if you like me have been left high and dry by GivEnergy, I cannot recommend this company enough. Give them a call.
I sent a message on their website regarding a problem I have on my Givenergy system. Although not supplied by Ronald, I thought it was worth an email. Within the hour on a Saturday, he phoned and we discussed the problem. He logged in remotely and gave excellent advice. I'm too far away for his on-site help but he did diagnose the problem and was happy also to chat through my thoughts about an upcoming solar/battery install I'm planning. Great bloke.... if only he was nearer!
4 quick checks before anything else
These checks take under three minutes and eliminate the most common causes without any specialist tools.
Open the GivEnergy portal or app and look at the live Solar power reading. It should show a positive kW value above 0.5–1 kW on a clear day. If it shows zero or a negligible figure, the issue is with generation itself — not with battery charging. Check for shade, dirty panels, or a tripped inverter before going further. See the solar not generating guide if generation is the problem.
Go to givenergy.cloud → My Inverter → System Mode Settings. If the mode shows Timed Discharge, the inverter is actively pushing power out of the battery and will not charge from solar at the same time. Switch to Eco Mode during daylight hours. Eco Mode is the solar-first mode — it automatically routes surplus solar into the battery.
Check the current battery SoC in the portal or app. If it reads 100% — or close to the maximum set in Battery Options — there is simply no room to charge. The system is working correctly. This is one of the most common "false faults" we see: the battery is full and the homeowner expects it to keep charging. Also check My Inverter → System Mode Settings → Battery Options → Operating Range — if the maximum SoC is set below 100%, the battery won't charge beyond that level.
In the portal go to My Inverter → Remote Control → Battery and check the Pause Battery setting. If it shows Paused, the battery is deliberately halted — it will not charge from solar (or any source) regardless of generation levels or system mode. Change it to Not paused to restore normal operation.
Important distinction: This guide covers the battery not charging from solar panels that are generating. If your solar panels are not producing power at all, that is a different fault — start with the solar not generating guide instead.
Wrong system mode — Timed Discharge prevents solar charging
Timed Discharge is designed to empty the battery during peak-price periods. When active, the inverter is pushing energy out of the battery — it cannot simultaneously accept solar charge. If a Timed Discharge window is active during daylight hours, solar surplus will export to grid instead of going into the battery.
Timed Discharge
Actively empties the battery during the set window. While discharging, solar surplus exports to grid rather than charging the battery.
Use for: peak-rate avoidance to sell stored energy or avoid high-rate import.
Eco Mode
Solar surplus charges the battery automatically. Home demand is met by solar first, then battery, then grid — in that priority order.
Use for: flat-rate tariffs and anyone who wants solar to charge the battery during the day.
Timed Charge
Forces grid charging during a set window. Outside the window, solar surplus can still charge the battery — though the primary intent is grid charging during cheap-rate hours.
Use for: time-of-use tariffs where you want to fill the battery at cheap overnight rates.
How to switch to Eco Mode for solar charging
Log into givenergy.cloud, click My Inverter, then navigate to System Mode Settings. The currently active mode is highlighted.
Click Eco Mode and press Submit. The change takes effect within a few minutes. You do not need to restart the inverter.
In the portal, return to the live overview. When solar generation exceeds home consumption, you should see the excess routing into the battery (battery power figure positive, SoC rising). If the battery SoC still isn't rising, check the remaining causes below.
Battery is full — SoC at maximum or operating range cap
GivEnergy will not charge the battery beyond its maximum SoC. This is correct behaviour — not a fault. There are two separate settings that define the maximum, and either can prevent solar charging from appearing to happen.
Current SoC in live monitoring
Look at the battery SoC in the portal right now. If it shows 100% (or close to it) on a sunny afternoon, the battery charged successfully earlier in the day — there's nothing left to fill. This is the system working correctly. Solar surplus at this point will export to grid rather than charge a full battery.
Operating Range maximum SoC
The Operating Range slider in Battery Options sets the ceiling for charging. If it's set to 80%, the battery will never charge above 80% from any source — including solar. If you've recently had a firmware update or someone changed this setting, it may be limiting charging unexpectedly.
Export limit throttling solar output before battery can charge
Many grid connections have an export limit imposed by the Distribution Network Operator (DNO) — typically 3.68 kW or less. The GivEnergy inverter enforces this by curtailing its total output. On high-irradiance days, the inverter may throttle solar output to stay within the export cap, which can reduce or block battery charging.
How export limiting affects battery charging
Solar charges the battery fully, then excess power flows to grid. The inverter can operate at maximum solar capacity for charging.
If the export limit is 0 kW (zero export), the inverter must consume all solar within the home or battery. On a bright day with a full battery and low home consumption, solar output may be completely curtailed — no generation, no charging.
How to check export limit settings
In the portal go to My Inverter → Export Limit Settings. Check whether export limiting is enabled and what the cap is set to.
If export limiting is active, check your portal's live power flow on a sunny day. If solar output appears low despite clear skies, the inverter may be curtailing generation to stay within the limit.
If the export limit was set by your DNO or installer during commissioning, do not increase it beyond the approved value — this is a G98/G99 compliance requirement. Contact your installer if you believe the limit is set incorrectly.
How export limiting works on GivEnergy, how to check and adjust the setting, and DNO compliance requirements.
Read the export limit guide →Low solar generation — not enough surplus to charge the battery
GivEnergy charges the battery from surplus solar — power that exceeds what the home is already consuming. In Eco Mode, if solar output barely covers home demand, there's little or nothing left to put into the battery. This is especially common in winter, on overcast days, and when panels are dirty or shaded.
Reasons solar output may be insufficient
How to check whether low generation is the issue
Compare your portal's solar output against your system's rated capacity on a clear, sunny day around solar noon (roughly 12:00–14:00 BST). A 4 kW system on a cloudless June midday should generate close to 3.5–4 kW. If it's generating significantly less, low generation is contributing to the lack of battery charging.
How to diagnose why solar output is zero or abnormally low — covers inverter faults, DC isolation, panel issues, and portal readings.
Read the solar generation guide →Low temperature lockout — BMS blocking all charging below 0 °C
GivEnergy lithium batteries include built-in low-temperature protection. If battery cell temperature falls below approximately 0 °C, the Battery Management System (BMS) refuses to accept a charge current to prevent lithium plating and irreversible cell damage. This applies to all charge sources — including solar. It is protective behaviour, not a fault.
How to check for temperature lockout
What to do
Temperature lockout is temporary and self-resolving — the battery will resume charging automatically once it warms above the threshold. No intervention is needed.
If your battery experiences frequent winter temperature lockouts, consider insulating the area around the battery installation. GivEnergy does not recommend installations in fully exposed, unheated outdoor locations.
Hardware fault — inverter, CT clamp, or BMS issue
If you've confirmed system mode, SoC, export limit, generation levels, and temperature are all fine, a hardware fault may be preventing solar charging. The most likely candidates are a CT clamp error (inverter misreading solar or grid), a BMS fault inside the battery, or an inverter communication failure.
CT clamp error — inverter misreading solar output
GivEnergy systems use CT clamps to measure both grid and solar current. If the solar CT clamp is installed incorrectly or has become loose, the inverter may be misreading solar generation. A solar CT clamp that reads zero or negative will make the inverter "think" no solar is available — so no battery charging is triggered even when panels are generating.
Do not touch the CT clamps — they sit on live cables. A remote diagnostic can confirm whether CT clamp readings appear correct from portal data. If a fault is confirmed, a site visit by a qualified engineer is required to reposition or replace the clamp.
BMS or battery communication fault
A fault in the battery's BMS or a CAN communication error between inverter and battery can prevent charging from any source. Check the portal event log for battery-related fault codes or comms errors. A red or amber LED on the battery unit itself is a strong indicator of a hardware fault requiring engineer attention.
When to stop self-diagnosing and call an engineer
Safety: All diagnostics on this page are done through the GivEnergy portal and app only. Do not open the inverter, battery enclosure, or consumer unit. Do not touch CT clamps, DC cables, or any electrical connections. Solar panels generate voltage even on cloudy days — the DC side of the system is live whenever any light reaches the panels.
We review your portal generation curves, CT clamp readings, and power flow logs to find the exact cause. Most solar charging issues are identified and resolved in a single remote session.
Zero or abnormally low solar output — inverter faults, DC isolation, and panel issues.
Battery not charging from grid during cheap-rate windows — Timed Charge, CT clamp, SoC limits.
How Eco Mode, Timed Charge, Timed Discharge, and Timed Export work — and which to use when.
Configuring and troubleshooting GivEnergy export limiting — DNO caps, zero export, G98/G99.
This is a brand-specific version of our general battery not charging guide, which covers all brands.
GivEnergy solar charging questions
Battery still not charging from solar? We'll find the cause.
Tell us what you're seeing — what your portal shows for solar generation, what system mode you're in, and what the battery SoC is doing during the day. We'll review your monitoring data and come back with a clear diagnosis.
- Not affiliated with GivEnergy Ltd
- Free remote diagnostic — pay only if we fix it
- Most solar charging issues identified from portal data
Got a solar fault or need a quick answer? Drop us a message — we usually reply within a few minutes. Mon–Fri, 9am–7pm.